Instruction Manual
• AUTO /
MANUAL
RANGE
• AUTO HOLD
• MAX / MIN
• BAR GRAPH
• BACKLIGHT
• LEAD
HOLDER
• 3-5/6 DIGIT
6000 COUNT
LCD
ENGLISH
8. Temperature:
Features:
SYMBOLS USED ON LCD
~
AC Measurement
DC Measurement
-
Negative DC Value
AT
Auto Range Active
O
.L.
Overload: Range Exceeded
Apo
Auto Power-Off Active
Low Battery
HOLD
Hold Active
MIN
Minimum Reading
M
AX
Maximum Reading
%
Duty Cycle Mode Frequency Mode
V
Voltage Measurement
A
Current in Amps
Ω
Resistance in Ohms Diode Test
F
Capacitance in Farads Continuity Test
Relative / Zero Mode
n
Nano 10
-9
µ
Micro 10
-6
m
Milli 10
-3
k
Kilo 10
3
M
Mega 10
6
°F
Degrees Fahrenheit
°C
Degrees Celsius
A-HOLD
Auto-Hold Active
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range Resolution Accuracy
600mV
˜
600V 0.1mV
˜
0.1V ± (0.5% + 4 digits)
1000V 1V ± (0.8% + 10 digits)
Overload Protection: 1000V Input Impedance (Nominal): 10MΩ, <100pF
AC Voltage Measurement
Range Resolution Accuracy
600mV 0.1mV
± (0.75% + 5 digits)
6V ~ 600V 1mV ~ 0.1V
1000V 1V ± (1.0% + 8 digits)
Overload Protection: 1000V RMS Input Impedance (Nominal): 10MΩ, <100pF
Frequency Response: 40 to 400 Hz Response: Averaging
DC Current Measurement
Range Resolution Accuracy
600µA ~ 400mA 0.1µA ~ 0.1mA ± (1.0% + 5 digits)
6A ~ 10A 1mA ~ 10mA ± (1.5% + 5 digits)
Overload Protection:
• µAmA: F440mA/1000V fuse
• A Input: F11A / 1000V fuse
AC Current Measurement
Range Resolution Accuracy
600µA ~ 400mA 0.1µA ~ 0.1mA ± (1.5% + 5 digits)
6A ~ 10A 1mA ~ 10mA ± (2.0% + 5 digits)
Overload Protection: µAmA: F440mA/1000V fuse / A Input: F11A / 1000V fuse
Frequency: 40 to 400Hz Response: Averaging
Resistance Measurement
Range Resolution Accuracy
600Ω
˜
6MΩ 0.1Ω
˜
0.001MΩ
± (1.0% + 5 digits)
60MΩ 0.01MΩ
± (1.5% + 10 digits)
Overload Protection: 600V RMS
Capacitance Measurement
Range Resolution Accuracy
60nF 0.01nF
± (3.5% + 6 digits)
600nF ~ 6000µF 0.1nF ~ 1µF
Overload Protection: 600V RMS
Frequency Measurement
Range Resolution Accuracy
99.99Hz
˜
499.9kHz 0.01Hz
˜
0.1kHz ± (0.1% + 3 digits)
Overload Protection: 600V RMS Sensitivity: >0.7V RMS
Duty Cycle Measurement
Range Resolution Accuracy
0.1
˜
99.9% 0.1% ± (0.2% per kHz + 0.1% + 5 digits)
Overload Protection: 600V RMS Sensitivity: < 50V
Frequency Range: <10kHz
Diode Test
Overload Protection Range Test Current Open Circuit Voltage
600V RMS 6.0V Appx. 0.25mA
<
1.8V DC (typ.)
Continuity Test
Overload Protection Open Circuit Voltage Threshold (Appx.)
600V RMS
<
0.44V
<40Ω
Temperature Measurement
Range Resolution Accuracy
-58 ~ 600°F 0.1°F ± (1.0% + 5.4°F)
-50 ~ 600°C 0.1°C ± (1.0% + 3.0°C)
600 ~ 1832°F 1°F ± (1.0% + 5.4°F)
-600 ~ 1000°C 1°C ± (1.0% + 3.0°C)
Overload Protection: 600V RMS
Thermocouple Accuracy: Not specified
Speci cations subject to change
7. Capacitance:
<
6000µF
Features:
HOLD
Safely discharge capacitor before measurement.
• Reading may take up to 60 seconds for large capacitors.
Do Not apply voltage to thermocouple.
• -58° to 1832°F (-50° to 1000°C)
Testing Fuses:
• When selecting µA or mA/A functions the meter will indicate
“LEAd” if the test leads are not properly connected to the meter.
• Note: This message remaining on the screen after properly
connecting the test leads is an indication that the fuse is open.
MAX/MINHOLDREL
A- HOLD
6. Frequency (Hz) / Duty Cycle <500kHz
Features:
HOLD
WARRANTY
www.kleintools.com/warranty
CLEANING
Clean the instrument by using a damp cloth. Do not use abrasive cleaners
or solvents.
Take care to keep the sensor lens clean at all times. Clean the lens using a soft
cloth or cotton swab with water or rubbing alcohol only, and allow the lens to
dry before use.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifications
section, allow the instrument to return to normal operating conditions before
using it.
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash. Items
must be properly disposed of in accordance with local regulations.