Klein-tools MM100 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messgeräte Klein-tools MM100 herunter. Klein Tools MM100 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street
Lincolnshire, IL 60069
www.kleintools.com
139569T Rev. 11/13 C
Dwg Name: MM100-139569TART Dwg No: 139569T
ECO No: 15144 Pkg Dwg Ref: 1719 Rev: C
Color Reference: N/A
ENGLISH
3-1/2 DIGIT
1999 COUNT
LCD
DATA HOLD
BATTERY TEST
KICKSTAND
LEAD HOLDER
COM
m
10A/500V
~
250mA/250V
~
600V MAX
CATIII
MM100
HOLD
200m
2
20m
200m
20
600
600
200
10A
9V
1.5V
200
2M
200k
20k
200
2k
200
BATT.
ENGLISH
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range Resolution Accuracy
200mV 0.1mV
± (0.5% + 3 digits)
2V 0.001V
20V 0.01V
200V 0.1V
600V 1V
Overload Protection: 600V RMS
Input Impedance (Nominal): > 1MΩ.
AC Voltage Measurement
Range Resolution Accuracy
200V 0.1V
± (1.2% + 5 digits)
600V 1V
Overload Protection: 600V RMS
Frequency: 50 ~ 60Hz
Input Impedance (Nominal): > 1MΩ.
Response: Averaging
DC Current Measurement
Range Resolution Accuracy
200μA 0.1μA
± (1.0% + 3 digit)20mA 0.01mA
200mA 0.1mA
10A 0.01A ± (3.0% + 5 digits)
Overload Protection:
mA Input: F250mA / 250V fast fuse
10A Input: F10A / 500V fast fuse
Max Input Current:
mA Input: 200mA DC / AC RMS
10A Input: 10A DC / AC RMS
Resistance Measurement
Range Resolution Accuracy
200Ω 0.1Ω
± (0.8% + 4 digit)
2kΩ 0.001kΩ
20kΩ 0.01kΩ
200kΩ 0.1kΩ
2MΩ 0.001MΩ
Overload Protection: 600V RMS
Battery Test
Type Resolution Test Current
1.5V 0.01V Appx. 15mA
9V 0.01V Appx. 30mA
Overload Protection: F250mA / 250V fast fuse
Diode Test
Overload Protection Test Current Open Circuit Voltage
600V RMS Appx. 1mA Appx. 3.0V DC
Continuity Test
Overload Protection Open Circuit Voltage
600V RMS Appx. 3.0V
WARRANTY
www.kleintools.com/warranty
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifications
section, allow the instrument to return to normal operating conditions before
using it.
DISPOSAL / RECYCLE
Caution: This symbol indicates that equipment and its accessories
shall be subject to a separate collection and correct disposal.
600V
10A
MM100
Instruction Manual
MM100 Instruction Manuals - MASTER.indd 1-4 11/20/2013 11:45:22 AM
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - Instruction Manual

CUSTOMER SERVICEKLEIN TOOLS, INC.450 Bond StreetLincolnshire, IL 60069www.kleintools.com139569T Rev. 11/13 CDwg Name: MM100-139569TART Dwg No: 139569

Seite 2

Dwg Name: MM100-139569TART Dwg No: 139569T ECO No: 15144 Pkg Dwg Ref: 1719 Rev: CColor Reference: N/AENGLISHA.B. Use properly safety rated

Kommentare zu diesen Handbüchern

Keine Kommentare